Skip to Main Content

Gastec Vinyl Chloride Gas Detector Tubes provide a convenient method for measuring vinyl chloride vapor concentrations in air using a compatible Gastec gas sampling pump.

Designed for on-site gas detection, industrial hygiene, workplace air monitoring, occupational safety, chemical processing, and environmental testing, Gastec detector tubes provide a simple visual method for measuring specific gas and vapor concentrations without requiring electronic gas detection equipment.

Multiple measuring ranges are available to accommodate different vinyl chloride monitoring applications, from low-level PPM measurements to higher percentage-level concentrations.

Gastec Vinyl Chloride Detector Tube Options:

Gastec 131LA Vinyl Chloride Detector Tubes:

  • Part Number: 131LA
  • Target Gas/Vapor: Vinyl Chloride
  • Vinyl Chloride Measuring Range: 0.25–54 PPM
  • Quantity: 5 detector tubes + 5 pretubes per box
  • Tests: 5 tests per box

Gastec 131 Vinyl Chloride Detector Tubes:

  • Part Number: 131
  • Target Gas/Vapor: Vinyl Chloride
  • Vinyl Chloride Measuring Range: 0.025–2%
  • Quantity: 5 detector tubes + 5 pretubes per box
  • Tests: 5 tests per box

Gastec 131L Vinyl Chloride Detector Tubes:

  • Part Number: 131L
  • Target Gas/Vapor: Vinyl Chloride
  • Vinyl Chloride Measuring Range: 0.1–6.6 PPM
  • Quantity: 5 detector tubes + 5 pretubes per box
  • Tests: 5 tests per box

Gastec 131LB Vinyl Chloride Detector Tubes:

  • Part Number: 131LB
  • Target Gas/Vapor: Vinyl Chloride
  • Vinyl Chloride Measuring Range: 0.25–70 PPM
  • Quantity: 10 tubes per box
  • Tests: 10 tests per box

Common Applications

Gastec Vinyl Chloride Gas Detector Tubes can be used with compatible Gastec sampling equipment for workplace air monitoring, industrial hygiene surveys, occupational exposure assessment, PVC and plastics manufacturing, chemical manufacturing and processing, vinyl chloride handling and storage, polymer production, manufacturing facilities, laboratory environments, environmental monitoring, process monitoring, and workplace safety applications where vinyl chloride may be present.

Important

A compatible Gastec Gas Sampling Pump is required to use these detector tubes. Please note that 131LA, 131, and 131L include pretubes and provide 5 tests per box, while 131LB contains 10 tubes and provides 10 tests per box.

Always select the appropriate detector tube and measuring range based on the anticipated vinyl chloride concentration and follow the manufacturer's sampling instructions and correction factors, when applicable, for the specific tube being used.

Need a Gastec Sampling Pump?

Gastec detector tubes require a compatible Gastec Gas Sampling Pump for proper sampling and measurement. Complete your gas detection setup with one of our available Gastec sampling pumps:

Already have a Gastec pump? Simply select the appropriate detector tube for your target gas and measuring range.

Choose Instrument Depot for dependable Gastec vinyl chloride detector tubes, gas sampling pumps, Gastec detector tubes, gas detection accessories, calibration gas, fixed flow regulators, and industrial gas detection equipment.